EPX-2500 High Performance Endoscopy Processor With 150W Xenon Light Source
  • EPX-2500 High Performance Endoscopy Processor With 150W Xenon Light Source
  • EPX-2500 High Performance Endoscopy Processor With 150W Xenon Light Source
  • EPX-2500 High Performance Endoscopy Processor With 150W Xenon Light Source
  • EPX-2500 High Performance Endoscopy Processor With 150W Xenon Light Source

EPX-2500 High Performance Endoscopy Processor With 150W Xenon Light Source

Model Number EPX-2500
Product Details
Highlight: 

EPX-2500 endoscopy processor with xenon light

,

high performance endoscopy processor 150W

,

endoscopy processor with xenon light source

Product Description
Product Description:
EPX-2500 High Performance Endoscopy Processor With 150W Xenon Light Source
1. Function Introduction:

The EPX-2500 is a user-friendly Xenon processor/light source. The control unit is easy to use and clearly displays all of the functions that are available for the integrated light source. This includes a blood vessel function which enhances the imaging of the vessels. Nine different light settings are available which offer the physician brightly illuminated images.

2. Parameters of EPX-2500

1. High-Definition endoscopy progressive scan imaging-increased image clarity and resolution
2. Compact, simplified combination platform-reduced footprint with greater ease-of-use
3. 150 watt xenon primary light source-cost-effective, highly-efficient illumination source
4. Automatic white balance-saves time while assuring color accuracy
5. Incremental electronic magnification up to 2X-allows for increased detail when required

EPX-2500 High Performance Endoscopy Processor With 150W Xenon Light Source

EPX-2500 High Performance Endoscopy Processor With 150W Xenon Light Source

The processor has a signal processing circuit that is provided with a digital signal processor. The digital processor generates a coarse video signal that is indirectly displayable on a video screen from image signals generated by a charge coupled device sensor .An auxiliary circuit has a correction circuit that generates another coarse video signal that is directly displayable on the video screen included for the following: (a) video endoscope (b) a camera for an endoscope.

Product Overview

The Fujifilm EPX-2500 is a combined endoscopy video processor and 150 W xenon light source in a single compact platform. Progressive-scan high-definition imaging, automatic white balance and incremental electronic magnification are controlled from one front panel, and the integrated light source offers nine illumination settings plus a blood-vessel enhancement mode that raises the contrast of mucosal vasculature. Combining processor and light source in one chassis reduces tower footprint and cabling, which matters in clinics running several procedure rooms.

Typical Clinical Use
Upper and lower GI endoscopy where enhanced vascular contrast supports lesion detection.
Screening and surveillance lists needing fast, repeatable white balance between scopes.
Clinics building a compact tower where one unit serves as both processor and light source.
Technical Highlights
Progressive-scan high-definition imaging for improved clarity and edge definition.
150 W xenon light source: bright, daylight-balanced illumination with nine light settings.
Blood-vessel enhancement function for highlighting mucosal vascular patterns.
Automatic white balance for colour accuracy without a manual setup step between cases.
Incremental electronic magnification from the front panel.
Compact combined platform: fewer cables and a smaller tower footprint.
Installation, Care and Quality Control

Allow clear airflow around the chassis and keep the rear filter clean — a blocked filter is the most common cause of lamp overheating and shutdown. Xenon lamps must be changed only after full cool-down, and the lamp envelope should never be touched with bare fingers. Run the automatic white balance with the scope attached and the light cable connected, and store spare lamps in the procedure room for high-volume days. Each unit is powered on, tested for image output and light intensity, and inspected for connector and fan condition before packing.

Ordering Notes
Which scopes are compatible?
The EPX-2500 is matched to Fujifilm 2500-series endoscopes and appropriate light cables. Tell us your scope models and we will confirm.
Is a spare lamp included?
Not by default. A spare xenon lamp can be added to the quotation on request.
Condition and delivery?
Condition is stated per unit; one piece minimum, dispatch normally within 5-7 working days, warranty terms quoted per order.
Product Specification Summary
ParameterValue
Model NumberEPX-2500